Dell OpenManage Server Administrator Version 6.5 Instrukcja Użytkownika Strona 248

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 282
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 247
248 omconfig storage Commands
Complete Syntax
omconfig storage enclosure action=settempprobes
controller=id enclosure=<ENCLOSUREID> index=id
minwarn=n maxwarn=n
where id is the controller ID and the temperature probe ID. The
<ENCLOSUREID> variable specifies the enclosure.
In this syntax, n is a user-specified value for the temperature in Celsius.
Example Syntax
For example, you may want to specify the minimum and maximum warning
thresholds for temperature probe 3 to 10 and 40° Celsius.
Example for SCSI, SATA, and ATA Controllers
In this example, temperature probe 3 resides in the enclosure attached to
connector 2 on controller 1. To set the temperature probe thresholds to
10 and 40° Celsius, type:
omconfig storage enclosure action=settempprobes
controller=1 enclosure=2 index=3 minwarn=10
maxwarn=40
omconfig Reset Temperature Probe Thresholds
Use the following omconfig command syntax to reset the minimum and
maximum warning temperature thresholds back to their default values.
NOTE: This command is not supported on SAS controllers.
Complete Syntax
omconfig storage enclosure action=resettempprobes
controller=id enclosure=<ENCLOSUREID> index=id
where id is the controller ID and the temperature probe ID. The
<ENCLOSUREID> variable specifies the enclosure.
Example Syntax
For example, you may want to reset the thresholds for temperature probe 3 to
the default values.
Przeglądanie stron 247
1 2 ... 243 244 245 246 247 248 249 250 251 252 253 ... 281 282

Komentarze do niniejszej Instrukcji

Brak uwag