omconfig: Managing Components Using the Instrumentation Service 103
attribute=
conredirect
setting=enabled |
disabled
enabled: Redirects the BIOS screen output
over serial port 1. Keyboard and text
output are redirected over serial port 2.
disabled: Turns off the BIOS console
redirection.
attribute=crab setting=enabled |
disabled
enabled: Enables BIOS console
redirection after system reboot.
disabled: Disables BIOS console
redirection.
NOTE: The attribute crab is valid only on
Dell PowerEdge
x
9
xx
systems.
attribute=cpuc1e setting=enabled |
disabled
enabled: Enables processor C1-E after
system reboot.
disabled: Disables processor C1-E after
system reboot.
attribute=cpuht setting=enabled |
disabled
enabled: Enables logical processor
hyperthreading.
disabled: Disables logical processor
hyperthreading.
attribute=cpuvt setting=enabled |
disabled
enabled: Enables virtualization.
disabled: Disables virtualization.
Table 4-3. BIOS Setup Settings on Systems Prior to PowerEdge
yx2x
Systems
(continued)
name=value pair 1
attribute=
name=value pair 2
setting=
Description