166 omconfig: Managing Components Using the Instrumentation Service
Table 4-26. Parameters of omconfig system platformevents
Event Name Description
alertsenable=true | false true: Enables generation of platform event filter alerts.
false: Disables generation of platform event filter
alerts.
NOTE: This setting is independent of the individual
platform event filter alert settings. For a platform event
filter to generate an alert, both the individual alert and
the global event alert are enabled.
event=batterywarn Sets action or enables or disables alert generation
when a battery device detects that the battery is
pending a failure condition.
event=batteryfail Sets action or enables or disables alert generation
when a battery device detects that the battery has
failed.
event=discretevolt Sets action or enables or disables alert generation
when a discrete voltage probe detects that the voltage
is too low for proper operation.
event=fanfail Sets action or enables or disables alert generation
when a fan probe detects that the fan is running too
slow or not running.
event=hardwarelogfail Enables or disables alert generation when a hardware
log detects a failure value.
event=intrusion Sets action or enables or disables alert generation
when a chassis is opened.
event=powerwarn Sets action or enables or disables alert generation
when a power device probe detects that the power
supply, voltage regulator module, or DC to DC
converter is pending a failure condition.
event=powerabsent Sets action or enables or disables alert generation
when a processor probe detects that the power supply
is absent.