254 omconfig storage Commands
Complete Syntax
omconfig storage controller action=quietalarm
controller=id
where id is the controller ID as reported by the omreport storage controller
command.
Example Syntax
To quiet the alarm on controller 1, type:
omconfig storage controller action=quietalarm
controller=1
omconfig Test Controller Alarm
Use the following omconfig command syntax to test the functionality of the
controller alarm. The alarm sounds for about two seconds. See the Dell
OpenManage Online Help for more information about Test Controller Alarm.
Complete Syntax
omconfig storage controller action=testalarm
controller=id
where id is the controller ID as reported by the omreport storage controller
command.
Example Syntax
To test the alarm on controller 1, type:
omconfig storage controller action=testalarm
controller=1