106 omconfig: Managing Components Using the Instrumentation Service
attribute=
embhypvisor
setting=enabled |
disabled
enabled: Enables the embedded
hypervisor.
disabled: Disables the embedded
hypervisor.
attribute=
embvideoctrl
setting=enabled |
disabled
enabled: Enables the embedded video
controller as the primary video device.
disabled: Disables the embedded video
controller as the primary video device.
attribute=
esataport
setting=off | auto off: Sets the embedded SATA port value
to off.
auto: Sets the embedded SATA port
value to auto.
attribute=
extserial
setting=com1 | com2
| rad
com1: Maps the external serial
connector to COM 1.
com2: Maps the external serial
connector to COM 2.
rad: Maps the external serial connector
to the remote access device.
attribute=fbr setting=9600 | 19200
| 57600 | 115200
9600: Sets the console redirection failsafe
baud rate to 9600 bits per second.
19200: Sets the console redirection failsafe
baud rate to 19200 bits per second.
57600: Sets the console redirection
failsafe baud rate to 57600 bits per
second.
115200: Sets the console redirection
failsafe baud rate to 115200 bits per
second.
Table 4-3. BIOS Setup Settings on Systems Prior to PowerEdge