208 omreport storage Commands
omreport Fan Status
Table 7-7 describes the syntax for the omreport fan commands.
Table 7-7. omreport Fan Status Commands
Required Command Levels
(1, 2, 3) and name=value pair
Optional name=value pairs Use
omreport storage
enclosure
Displays property
information for all
enclosures attached to the
system.
controller=id enclosure=
<ENCLOSUREID>
info=fans
where id is the controller number
and ENCLOSUREID is the
enclosure number.
For example: controller=0
enclosure=2
NOTE: For SCSI controllers, the
ID specified in enclosure=
<ENCLOSUREID> is the connector
number and for Serial Attached
SCSI (SAS) controllers, ID is the
connectorNumber:EnclosureIndex.
Displays the information
about the fans for the
specific enclosure.
controller=id enclosure=
<ENCLOSUREID>
info=fans index=n
where id is the controller number
and ENCLOSUREID is the
enclosure number and “n” is the
number of a fan.
For example: controller=0
enclosure=2 info=fans index=1