222 omconfig storage Commands
To obtain these values, type omreport storage controller to display the
controller IDs and then type omreport storage pdisk controller=ID to
display the IDs for the physical disks attached to the controller.
Example Syntax
To erase the data on physical disk 3 on connector 0 of controller 1:
For SCSI, SATA, and ATA controllers:
omconfig storage pdisk action=instantsecureerase
controller=1 pdisk=0:3
For SAS controllers:
omconfig storage pdisk action=remove controller=1
pdisk=0:2:3
NOTE: On a SAS controller, the physical disk resides in enclosure 2.
omconfig Initialize Physical Disk
Use the following omconfig command syntax to initialize a physical disk.
Complete Syntax
omconfig storage pdisk action=initialize
controller=id pdisk=<PDISKID>
where id is the controller ID. The <PDISKID> variable specifies the
physical disk.
To obtain these values, type omreport storage controller to display the
controller IDs and then type omreport storage vdisk controller=ID to display
the IDs for the physical disks attached to the controller.
Example Syntax
To initialize physical disk 4 on controller 1, type:
omconfig storage pdisk action=initialize
controller=1 pdisk=4