Dell OpenManage Server Administrator Managed Node for Fluid Cache for DAS Instrukcja Użytkownika Strona 162

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 316
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 161
162 omconfig: Managing Components Using the Instrumentation Service
Example Set Alert Action Commands
The following examples are valid example commands. For each successful
command issued, the following message is displayed:
Alert action(s) configured successfully.
For Current Probe Actions
To disable system console alert if a current probe detects a warning event,
type:
omconfig system alertaction event=currentwarn
alert=false
or
omconfig servermodule alertaction event=
currentwarn alert=false
To enable broadcast messages if a current probe detects a failure event, type:
omconfig system alertaction event=currentfail
broadcast=true
or
omconfig servermodule alertaction event=
currentfail broadcast=true
For Fan Probe Actions
To generate alerts when a fan probe detects a failure value, type:
omconfig system alertaction event=fanfail alert=
true
or
omconfig servermodule alertaction event=fanfail
alert=true
event=storagectrlbatteryfail Sets actions when a storage controller battery detects a
failure value.
NOTE: This event is not available on Blade systems.
Table 4-23. Events for Which You Can Set Alert Actions
(continued)
Event Name Description
Przeglądanie stron 161