cfgRhostsSyslogServer1 (Read/Write)
Description Specifies the first of three possible remote syslog servers
to store the RAC and SEL logs.This property is only valid if
cfgRhostsSyslogEnable is set to 1 (enabled).
Legal Values
Valid hostname or IPv4 or IPv6 address.
Default <
blank
>
cfgRhostsSyslogServer2 (Read/Write)
Description Specifies the second of three possible remote syslog
servers to store the RAC and SEL logs.. This property is
only valid if cfgRhostsSyslogEnable is set to 1 (enabled).
Legal Values
Valid hostname or IPv4 or IPv6 address.
Default <
blank
>
cfgRhostsSyslogServer3 (Read/Write)
Description Specifies the third of three possible remote syslog servers
to store the RAC and SEL logs. This property is only valid if
cfgRhostsSyslogEnable is set to 1 (enabled).
Legal Values
Valid hostname or IPv4 or IPv6 address.
Default <
blank
>
cfgRhostsSyslogPowerLoggingEnabled
Description Enables or disables power consumption logging to remote
syslog servers.
NOTE: Remote syslog must be enabled and one or
more remote syslog servers must be configured for
power consumption to be logged.
Legal Values
1 (enabled)
0 (disabled)
Default 0
cfgRhostsSyslogPowerLoggingInterval
Description
Specifies the power consumption collection/logging interval.
Legal Values 1–1440 (minutes)
Default 5