Use this object with the config or getconfig subcommands.
To use this object property for CMC, you must have Chassis Configuration Administrator privilege.
NOTE: For CMC, you can configure any setting that is not preceded by the hash sign (#) in the output. To modify a
configurable object, use the -o option.
Use the -m option to apply this setting to iDRAC.
The following sections provide information about the objects in the cfgRacTuning group.
cfgRacTuneDefCredentialWarningEnable
Description Enables or disables the display of the default password
warning page.
Legal Values
0 and 1
Default 1
cfgRacTuneRemoteRacadmEnable (Read/Write)
Description Enables or disables the Remote RACADM interface.
Legal Values
1 (TRUE)
0 (FALSE)
Default 1
cfgRacTuneHttpPort (Read/Write)
Description Specifies the port number to use for HTTP network
communication.
Legal Values 10–65535
NOTE: The following port numbers are reserved and
cannot be used: 21, 68, 69, 123, 161, 546, 801, 4096,
5988, 5989, 6900, 9000, 60106.
Default 80
cfgRacTuneHttpsPort (Read/Write)
Description Specifies the port number to use for HTTPS network
communication with.
Legal Values 10–65535
NOTE: The following port numbers are reserved and
cannot be used: 21, 68, 69, 123, 161, 546, 801, 4096,
5988, 5989, 6900, 9000, 60106.
Default 443