Dell Chassis Management Controller Version 1.0 for PowerEdge VRTX Podręcznik Użytkownika Strona 120

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 155
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 119
Default 0
cfgRacTuneIpBlkFailCount (Read/Write)
Description The maximum number of login failures to occur within the
window (cfgRacTuneIpBlkFailWindow) before login
attempts from the IP address are rejected.
Legal Values 2 – 16
Default 5
cfgRacTuneIpBlkFailWindow (Read/Write)
Description Defines the time span in seconds that the failed attempts
are counted. When failure attempts age beyond this limit,
they are dropped from the count.
Legal Values
2–65535
Default 60
cfgRacTuneIpBlkPenaltyTime (Read/Write)
Description Defines the time span in seconds that session requests
from an IP address with excessive failures are rejected.
Legal Values
2–65535
Default 300
cfgRacTuneSshPort (Read/Write)
Description Specifies the port number used for the SSH interface.
Legal Values
10–65535
Default 22
cfgRacTuneTelnetPort (Read/Write)
Description Specifies the port number used for iDRAC or CMC Telnet
interface.
NOTE: For CMC, the following port numbers are
reserved and cannot be used: 21, 68, 69, 123, 161, 546,
801, 4096, 5988, 5989, 6900, 9000, 60106.
Legal Values
For iDRAC: 1 – 65535
For CMC: 10 – 65535
Default 23