Dell Chassis Management Controller Version 1.0 for PowerEdge VRTX Podręcznik Użytkownika Strona 38

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 155
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 37
<Server#> <Presence> <DC1 Type> <DC1 State> <DC2 Type> <DC2 State>
server-1 Present PCIe OK PCIe OK
server-2 Not Present None N/A None N/A
server-3 Present PCIe OK None N/A
server-4 Not Present None N/A None N/A
getdcinfo -n
<
Server#> <Presence> <DC1 Model Name> <DC2 Model Name>
server-1 Present None None
server-2 Not Present None None
server-3 Not Present None None
server-4 Present None Broadcom M5708t
getflexaddr
Description Displays enabled or disabled status for the entire chassis.
If used with -i, the command displays MACs/WWN on a
per-slot–basis.
To use this subcommand, you must have CMC Login User
privilege.
NOTE: If FlexAddress is not activated on the chassis,
the command displays server-assigned MAC/WWN
addresses. If the slot is empty, the command leaves
the server-assigned MAC/WWN addresses blank. If
an external console controls the MAC/WWN
addresses, the command displays an externally
managed message.
Synopsis
racadm getflexaddr [-i <slotNum>]
Input -i <
slotNum
> — Specifies the slot information to be
displayed. <
slotNum
> must be from 1 to 4.
Example
Display current FlexAddress settings for all the slots and fabrics.
racadm getflexaddr
<Slot#> <Status> <Server Presence>
1 Enabled Present
2 Enabled Present
3 Enabled Not Present
38
Przeglądanie stron 37