cfgKvmSlot2Enable
cfgKvmSlot3Enable
cfgKvmSlot4Enable
Legal Values 0 disables the mapping and 1 enables the mapping.
Default None
cfgDvdInfo
This group is used to view the mapping information for the DVD drive in the chassis.
Use this object with the config or getconfig subcommands.
To use this object property, you must have the Chassis Configuration Administrator privilege.
cfgDvdMapping Read or Write
Description Maps the slots to the DVD drive in the chassis:
Legal Values 1, 2, 3, and 4 are the slot numbers that are specified.
Default 1
cfgDvdSlot<num>Enable Read or Write
Description Enable the slots (1 to 4) to access the DVD:
cfgDvdSlot1Enable
cfgDvdSlot2Enable
cfgDvdSlot3Enable
cfgDvdSlot4Enable
Legal Values 0 disables the mapping and 1 enables the mapping.
Default None
cfgLcdInfo
This group is used to view the LCD locale, LCD orientation, and to check if the buttons to navigate through the LCD menu
are enabled.
Use this object with the config or getconfig subcommands.
To use this object property, you must have the Chassis Configuration Administrator privilege.
cfgAlerting
This group is enables or disables SNMP event trap alerting and sets the event filter.
Use this object with the config or getconfig subcommands.
To use this object property, you must have the Chassis Configuration Administrator privilege.