cfgAlertingEnable
Description Enables or disables event traps on the CMC.
Legal Values
1 (true)
0 (false)
Default None
cfgAlertingFilterMask
Description Sets the event filter.
Legal Values Hex values 0x0 – 0x1fffffff
Default 0x17ff8db
cfgAlertingSourceEmailName
Description Specifies the e-mail address used to send e-mail notifications when an event
occurs.
Legal Values None
Default None
Examples
racadm getconfig -g cfgAlerting -o cfgAlertingSourceEmailName
racadm config -g cfgAlerting -o cfgAlertingSourceEmailName [email protected]
Object value modified successfully.
cfgLcdLocale
Description Specifies the Language (locale) for the Blade Chassis LCD interface.
Legal Values de, fr, en, es, ja, zh-cn.
Default en
Example
racadm config -g cfgLcdInfo -o cfgLcdLocale en
Object value modified successfully.