Storage Management Message Reference 193
2318 Problems with
the battery or
the battery
charger have
been detected.
The battery
health is poor.
Warning /
Non-critical
Cause: The battery or
the battery charger is
not functioning
properly.
Action: Replace the
battery pack.
Clear Alert:
None
Related
Alert
Number:
2188
LRA
Number:
2100
1153
2319 Single-bit
ECC error.
The DIMM is
degrading.
Warning /
Non-critical
Cause: The DIMM is
beginning to
malfunction.
Action: Replace the
DIMM to avoid data
loss or data corruption.
The DIMM is a part of
the controller battery
pack. See your hardware
documentation for
information on
replacing the DIMM or
contact technical
support.
Clear Alert:
None
Related
Alert
Number:
2320
LRA
Number:
2060
753
Table 3-4. Storage Management Messages