256 System Event Log Messages for IPMI Systems
<Power Supply Sensor
Name> power supply sensor
returned to normal state.
Information This event is generated when the
power supply that failed or
removed was replaced and the
state has returned to normal.
<Entity Name> PS
Redundancy
sensor redundancy
degraded.
Information Power supply redundancy
is degraded if one of the
power supply sources is
removed or failed.
<Entity Name> PS
Redundancy
sensor redundancy lost.
Critical Power supply redundancy is lost
if only one power supply is
functional.
<Entity Name> PS
Redundancy
sensor redundancy
regained.
Information This event is generated if the
power supply has been
reconnected or replaced.
<Power Supply Sensor
Name> predictive failure
was asserted
Critical This event is generated when the
power supply is about to fail.
<Power Supply Sensor
Name> input lost was
asserted
Critical This event is generated when the
power supply is unplugged.
<Power Supply Sensor
Name> predictive failure
was deasserted
Information This event is generated when the
power supply has recovered from
an earlier predictive failure event.
<Power Supply Sensor
Name> input lost was
deasserted
Information This event is generated when the
power supply is plugged in.
PS 1 Status: Power supply
sensor for PS 1, presence
was asserted
Information This event is generated when the
power supply is plugged in.
PS 1 Status: Power supply
sensor for PS 1, presence
was deasserted
Critical This event is generated when the
power supply is removed.
Table 4-5. Power Supply Events
(continued)
Event Message Severity Cause