114 Storage Management Message Reference
2126 SCSI sense
sector reassign
Warning /
Non-critical
Cause: A sector of the
physical disk is
corrupted and data
cannot be maintained
on this portion of the
disk. This alert is for
informational purposes.
CAUTION: Any
data residing on the
corrupt portion of the
disk may be lost and you
may need to restore your
data from backup.
Action: If the physical
disk is part of a non-
redundant virtual disk,
then back up the data
and replace the physical
disk.
CAUTION:
Removing a physical
disk that is included in a
non-redundant virtual
disk causes the virtual
disk to fail and may
cause data loss.
If the disk is part of a
redundant virtual disk,
then any data residing
on the corrupt portion
of the disk is reallocated
elsewhere in the
virtual disk.