System Event Log Messages for IPMI Systems 255
Power Supply Events
The power supply sensors monitor the functionality of the power supplies.
These messages provide status and warning information for power supplies
for a particular system.
CPU <number> terminator is
present.
Information This event is generated if the
terminator is present on a
processor slot.
CPU <number> terminator is
absent.
Warning This event is generated if the
terminator is missing on an
empty processor slot.
CPU <number> is throttled. Warning This event is generated when the
processor slows down to prevent
overheating.
CPU <number> is absent. Critical This event is generated when the
system could not detect the
processor.
CPU <number> is operating
correctly.
Information This event is generated when the
processor recovered from an
error.
CPU <number> is configured
correctly.
Information The specified CPU is configured
correctly.
Table 4-5. Power Supply Events
Event Message Severity Cause
<Power Supply Sensor
Name> power supply sensor
removed.
Critical This event is generated when the
power supply sensor is removed.
<Power Supply Sensor
Name> power supply sensor
AC recovered.
Information This event is generated when the
power supply has been replaced.
Table 4-4. Processor Status Events