Storage Management Message Reference 109
2122 Redundancy
degraded
Warning /
Non-critical
Cause: One or more of
the enclosure
components has failed.
For example, a fan or
power supply may have
failed. Although the
enclosure is currently
operational, the failure of
additional components
could cause the
enclosure to fail.
Action: Identify and
replace the failed
component. To identify
the failed component,
select the enclosure in
the tree view and click
the Health subtab.
Any failed component
is identified with a red
X on the enclosure’s
Health subtab.
Alternatively, you can
select the Storage
object and click the
Health subtab.
Clear Alert
Status:
2124
Related
Alert
Number:
2048
LRA
Number:
2090
1305
Table 3-4. Storage Management Messages
(continued)
Event
ID
Description Severity Cause and Action Related
Alert
Information
SNMP
Trap
Numbers