104 Storage Management Message Reference
2112 Enclosure was
shut down
Critical /
Failure / Error
Cause: The physical
disk enclosure is either
hotter or cooler than
the maximum or
minimum allowable
temperature range.
Action: Check for
factors that may cause
overheating or excessive
cooling. For example,
verify that the enclosure
fan is working. You
should also check the
thermostat settings and
examine whether the
enclosure is located
near a heat source.
Make sure the enclosure
has enough ventilation
and that the room
temperature is not too
hot or too cold. See the
enclosure
documentation for
more diagnostic
information.
Clear Alert
Number:
None
Related
Alert
Number:
None
LRA
Number:
2091
854
Table 3-4. Storage Management Messages
(continued)
Event
ID
Description Severity Cause and Action Related
Alert
Information
SNMP
Trap
Numbers
Przeglądanie stron 103