274 System Event Log Messages for IPMI Systems
A fatal IO error detected
on a component at bus
<number> device <number>
function <number>.
Critical This error is generated when a
fatal IO error is detected.
A fatal IO error detected
on a component at slot
<number>.
Critical This error is generated when a
fatal IO error is detected.
A non-fatal PCIe error
detected on a component at
bus <number> device
<number> function
<number>.
Warning This event is generated in
association with a CPU IERR.
A non-fatal PCIe error
detected on a component at
slot <number>.
Warning This event is generated in
association with a CPU IERR.
A non-fatal IO error
detected on a component at
bus <number> device
<number> function
<number>.
Warning This event is generated in
association with a CPU IERR
and indicates the PCI/PCIe
device that caused the CPU
IERR.
Memory device was added at
location <location>.
Information This event is generated when
memory is added to the system.
Memory device is removed
from location <location>.
Information This event is generated when
memory is removed from the
system.
Unsupported memory
configuration; check
memory device at location
<location>.
Critical This event is generated when
memory configuration is
incorrect for the system.
Correctable memory error
rate exceeded for
<location>.
Warning This event is generated when
correctable ECC errors have
increased from a normal rate.
Correctable memory error
rate exceeded for
<location>.
Critical This event is generated when
correctable ECC errors reach a
critical rate.
Table 4-12. BIOS Generated System Events