Dell OpenManage Server Administrator Managed Node for Fluid Cache for DAS Podręcznik Użytkownika Strona 144

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 292
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 143
144 Storage Management Message Reference
2190 The controller
has detected a
hot-add of an
enclosure.
OK / Normal /
Informational
Cause: This alert is for
informational purposes.
Action: None
Clear Alert:
None
Related
Alert: None
LRA
Number:
None
751
2191 Multiple
enclosures are
attached to the
controller. This
is an
unsupported
configuration.
Critical /
Failure / Error
Cause: There are too
many enclosures
attached to the
controller port. When
the enclosure limit is
exceeded, the controller
loses contact with all
enclosures attached to
the port.
Action: Remove the last
enclosure. You must
remove the enclosure
that has been added last
and is causing the
enclosure limit to
exceed.
Clear Alert:
None
Related
Alert
Number:
2211
LRA
Number:
2091
854
Table 3-4. Storage Management Messages
(continued)
Event
ID
Description Severity Cause and Action Related
Alert
Information
SNMP
Trap
Numbers
Przeglądanie stron 143
1 2 ... 139 140 141 142 143 144 145 146 147 148 149 ... 291 292

Komentarze do niniejszej Instrukcji

Brak uwag