System Event Log Messages for IPMI Systems 267
Intrusion Events
The chassis intrusion messages are a security measure. Chassis intrusion
alerts are generated when the system's chassis is opened. Alerts are sent to
prevent unauthorized removal of parts from the chassis.
Fault detected on drive
<Drive #>.
Critical This event is generated
when the specified drive in
the array is faulty.
Table 4-11. Intrusion Events
Event Message Severity Cause
<Intrusion sensor
Name> sensor detected
an intrusion.
Critical This event is generated when the
intrusion sensor detects an intrusion.
<Intrusion sensor
Name> sensor returned
to normal state.
Information This event is generated when the
earlier intrusion has been corrected.
<Intrusion sensor
Name> sensor intrusion
was asserted while
system was ON
Critical This event is generated when the
intrusion sensor detects an intrusion
while the system is on.
<Intrusion sensor
Name> sensor intrusion
was asserted while
system was OFF
Critical This event is generated when the
intrusion sensor detects an intrusion
while the system is off.
The chassis is open. Critical This event is generated when the
intrusion sensor detects an intrusion.
The chassis is closed. Information This event is generated when the
earlier intrusion has been corrected.
The chassis is open
while the power is on.
Critical This event is generated when the
intrusion sensor detects an intrusion
while the system is on.
Table 4-10. Drive Events
(continued)
Event Message Severity Cause
Przeglądanie stron 266