204 Storage Management Message Reference
2337 The controller is
unable to
recover cached
data from the
battery backup
unit (BBU).
Critical /
Failure / Error
Cause: The controller
was unable to recover
data from the cache.
This may occur when
the system is without
power for an extended
period of time when the
battery is discharged.
Action: Check if the
battery is charged and
in good health. When
the battery charge is
unacceptably low, it
cannot maintain cached
data. Check if the
battery has reached its
recharge limit. The
battery may need to be
recharged or replaced.
Clear Alert:
None
Related
Alert: None
LRA
Number:
2101
1154
2338 The controller
has recovered
cached data
from the BBU.
OK / Normal /
Informational
Cause: This alert is for
informational purposes.
Action: None
Clear Alert:
None
Related
Alert: None
LRA
Number:
None
1151
2339 The factory
default
settings have
been restored.
OK / Normal /
Informational
Cause: This alert is for
informational purposes.
Action: None
Clear Alert:
None
Related
Alert: None
LRA
Number:
None
751
Table 3-4. Storage Management Messages