100 Storage Management Message Reference
2108 SMART
warning
Warning /
Non-critical
Cause: A disk has
received a SMART alert
(predictive failure).
The disk is likely to fail
in the near future.
Action: Replace the
disk that has received
the SMART alert. If the
physical disk is a
member of a
non-redundant virtual
disk, then back up the
data before replacing
the disk.
CAUTION:
Removing a physical
disk that is included in a
non-redundant virtual
disk causes the virtual
disk to fail and may
cause data loss.
Clear Alert
Number:
None
Related
Alert
Number:
None
LRA
Number:
2070
903
Table 3-4. Storage Management Messages