Arguments
arg1 =
sleeve number
Detailed
Description
The user account does not have sufficient privileges to perform virtual reseat operation on the
sleeve specified in the message. Server administration privilege is required to perform virtual
reseat operation.
Recommended
Response Action
Use a different user account that has server administration privileges, and retry the operation.
For more information, contact your administrator.
Category Audit
SubCategory CMC = Chassis Management Controller
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
CMC8533
Message Unable to read the FRU information, status =
arg1
Arguments
arg1 =
status value
Detailed
Description
Unable to read the header of the extended FRU information. This can occur if there is a
problem in the communication between the CMC and the server.
Recommended
Response Action
Remove and reinsert the server. The CMC will retry the read operation of the FRU information.
If the issue persists, contact your service provider.
Category Audit
SubCategory CMC = Chassis Management Controller
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE