Przeglądanie stron 577
Category Audit
SubCategory PWR = Power Usage
Severity Severity 1 (Critical)
Trap/EventID 8417
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#EMAIL Alert;#LC Log;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
PWR8564
Message Unable to turn on the Server
arg1
because the power request exceeded the System Input Power
Cap.
Arguments
arg1 =
slot number
Detailed
Description
The server identified in the message was not turned on because the available power is less
than the requested power.
Recommended
Response Action
Utilize the Chassis Management Controller web interface to check the System Input Max
Power Capacity Power and server power requirements. If sufficient power is available, retry
the operation. Otherwise, increase the System Input Power Cap value.
Category Audit
SubCategory PWR = Power Usage
Severity Severity 2 (Warning)
Trap/EventID 8418
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#EMAIL Alert;#LC Log;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
PWR8565
Message Unable to turn off the Server
arg1
due to iDRAC communication issue.
Arguments
arg1 =
server number
578