Detailed
Description
The Chassis manager is unable to power on adapter. Possible reasons for power failures are:
1. Adapter not a approved by Dell and therefore not within require specifications 2. Adpater not
fully inserted in the slot 3. Auxiliary power cable not connected (applicable to slot 1 - 3 only) 4,
Adapter is damaged
Recommended
Response Action
Make sure a supported PCIe device is used and that it is properly inserted in the PCIe slot. For
a list of supported devices, contact the service provider.
Category System Health
SubCategory IOV = IO Virtualization
Severity Severity 2 (Warning)
Trap/EventID 2554
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#EMAIL Alert;#LCD;#LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
IOV107
Message PCIe slot
arg1
adapter
arg2
removed while powered on.
Arguments
arg1 =
adapter slot number
arg2 =
device ID
Detailed
Description
The Chassis manager has detected the removal of a PCIe adapter card which was assigned to
a powered on server.
Recommended
Response Action
Power down the affected server(s) and then power on the server(s). Note: OS reboot will not
correct this issue.
Category System Health
SubCategory IOV = IO Virtualization
Severity Severity 1 (Critical)
Trap/EventID 2553
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#EMAIL Alert;#LCD;#LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE