Dell Chassis Management Controller Version 1.0 for PowerEdge VRTX Podręcznik Użytkownika Strona 365

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 931
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 364
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
MEM0016
Message Memory device at location(s)
arg1
is operating correctly.
Arguments
arg1 =
location
Detailed
Description
None
Recommended
Response Action
No response action is required.
Category System Health
SubCategory MEM = Memory
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
MEM0001
Message Multi-bit memory errors detected on a memory device at location(s)
arg1
.
Arguments
arg1 =
location
Detailed
Description
The memory has encountered a uncorrectable error. System performance may be degraded.
The operating system and/or applications may fail as a result.
Recommended
Response Action
Re-install the memory component. If the problem persists, contact technical support. Refer to
the product documentation to choose a convenient contact method.
Category System Health
SubCategory MEM = Memory
Severity Severity 1 (Critical)
Trap/EventID FALSE
365
Przeglądanie stron 364
1 2 ... 360 361 362 363 364 365 366 367 368 369 370 ... 930 931

Komentarze do niniejszej Instrukcji

Brak uwag