25
PDR Event Messages
PDR1
Message
arg1
copyback stopped for rebuild.
Arguments
arg1 =
physical disk
Detailed
Description
This message is generated after a copyback stops on a physical disk during a rebuild
operation.
Recommended
Response Action
Wait for rebuild to finish, then copyback should resume.
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 2 (Warning)
Trap/EventID 4346
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
PDR2
Message Insufficient space available on
arg1
to perform a copyback operation.
Arguments
arg1 =
physical disk
Detailed
Description
This message is generated if a physical disk does not have enough space to do a copyback
operation.
Recommended
Response Action
Replace the physical disk with a larger physical disk, and then restart the copyback operation.
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 2 (Warning)