Trap/EventID 2185
LCD Message Output under voltage fault detected on PSU <number>.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
PSU0041
Message An output over voltage fault detected on power supply
arg1
.
Arguments
arg1 =
number
Detailed
Description
none
Recommended
Response Action
1) Remove the power supply input cord and then remove power supply. 2) Re-install the power
supply and then re-install the power supply cord. 3) If the issue persists, contact technical
support. Refer to the product documentation to choose a convenient contact method.
Category System Health
SubCategory PSU = Power Supply
Severity Severity 1 (Critical)
Trap/EventID 2185
LCD Message Output over voltage fault on PSU <number>. Check PSU
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
PSU0042
Message An output over current fault detected on power supply
arg1
.
Arguments
arg1 =
number
Detailed
Description
none
Recommended
Response Action
1) Remove the power supply input cord and then remove power supply. 2) Re-install the power
supply and then re-install the power supply cord. 3) If the issue persists, contact technical
support. Refer to the product documentation to choose a convenient contact method.
Category System Health