Dell Chassis Management Controller Version 1.0 for PowerEdge VRTX Podręcznik Użytkownika Strona 488

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 931
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 487
Arguments
arg1 =
number
arg2 =
bay
Detailed
Description
The controller received a SMART error from the drive. The drive is operational but needs
replacement.
Recommended
Response Action
The drive will need replacement at the next service window.
Category System Health
SubCategory PDR = Physical Disk
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PDR1003
Message Drive
arg1
in disk drive bay
arg2
is the hot-spare drive.
Arguments
arg1 =
number
arg2 =
bay
Detailed
Description
None
Recommended
Response Action
No response action is required.
Category System Health
SubCategory PDR = Physical Disk
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
488
Przeglądanie stron 487
1 2 ... 483 484 485 486 487 488 489 490 491 492 493 ... 930 931

Komentarze do niniejszej Instrukcji

Brak uwag