Category System Health
SubCategory VLT = Voltage
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
VLT0218
Message The
arg1
voltage is less than the lower warning threshold.
Arguments
arg1 =
name
Detailed
Description
System hardware detected an over voltage or under voltage condition. If multiple voltage
exceptions occur consecutively the system may power down in failsafe mode.
Recommended
Response Action
1) Review system logs for power supply exceptions 2) Reduce system to minimum
configuration, inspect and re-install system cables. 3) If the problem persists, contact technical
support. Refer to the product documentation to choose a convenient contact method.
Category System Health
SubCategory VLT = Voltage
Severity Severity 2 (Warning)
Trap/EventID 2170
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
VLT0219
Message The
arg1
voltage is less than the lower critical threshold.
Arguments
arg1 =
name
Detailed
Description
System hardware detected an over voltage or under voltage condition. If multiple voltage
exceptions occur consecutively the system may power down in failsafe mode.