Dell Chassis Management Controller Version 1.0 for PowerEdge VRTX Podręcznik Użytkownika Strona 375

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 931
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 374
Category System Health
SubCategory MEM = Memory
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
MEM1205
Message Memory mirror redundancy is lost. Check memory device at location(s)
arg1
.
Arguments
arg1 =
location
Detailed
Description
The memory may not be seated correctly, misconfigured, or has failed.
Recommended
Response Action
Review system logs for memory exceptions. Re-install memory at location <location>
Category System Health
SubCategory MEM = Memory
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message Memory mirror lost on <location>. Power cycle system
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
MEM1206
Message Memory mirror redundancy is degraded. Check memory device at location
arg1
.
Arguments
arg1 =
location
Detailed
Description
The memory may not be seated correctly, misconfigured, or has failed.
375
Przeglądanie stron 374
1 2 ... 370 371 372 373 374 375 376 377 378 379 380 ... 930 931

Komentarze do niniejszej Instrukcji

Brak uwag