SEL0010
Message System event log (SEL) is almost full.
Detailed
Description
When the event log is full, additional events are not written to the log or older events will be
overwritten and lost. (IPMI sensor type code 10h - offset 05h)
Recommended
Response Action
Backup and clear log at the next maintained time.
Category System Health
SubCategory SEL = Sys Event Log
Severity Severity 2 (Warning)
Trap/EventID 2378
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
SEL0012
Message Could not create or initialize the system event log.
Detailed
Description
if the system event log failed to initialize platform status and failure events are not captured.
Some management software will not report platform exceptions.
Recommended
Response Action
Reboot the management controller or iDRAC. Cycle system input power. If problem persists call
support.
Category System Health
SubCategory SEL = Sys Event Log
Severity Severity 1 (Critical)
Trap/EventID 2377
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
SEL0013
Message The system event log was created or initialized successfully.
692
Przeglądanie stron 691