Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
ENC27
Message SAS or SATA mixing of physical disks is not supported within the
arg1
.
Arguments
arg1 =
Enclosure Name
Detailed
Description
The enclosure cannot support both SAS and SATA physical disks. Physical disks may be
disabled. This alert is provided for informational purposes.
Recommended
Response Action
No response action is required.
Category Storage
SubCategory ENC = Storage Enclosr
Severity Severity 3 (Informational)
Trap/EventID 4339
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
ENC28
Message Enclosure Management Module (EMM) firmware version mismatch detected in
arg1
.
arg2arg3
.
Arguments
arg1 =
enclosure name
arg2 =
EMM 0 version
arg3 =
EMM 1 version
Detailed
Description
The firmware on the EMM modules is not the same version. Both modules must have the same
firmware version. This message is caused when you attempt to insert an EMM module that has
a different firmware version than an existing module.
Recommended
Response Action
Upgrade to the same version of the firmware on both EMM modules.
Category Storage
SubCategory ENC = Storage Enclosr