Przeglądanie stron 820
Category Storage
SubCategory TMP = Temperature
Severity Severity 2 (Warning)
Trap/EventID 4210
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
TMP1001
Message
arg1
has crossed the minimum warning threshold.
Arguments
arg1 =
tempsensor name
Detailed
Description
The enclosure is too cold.
Recommended
Response Action
Check whether the thermostat setting is too low and whether the room temperature is too cool.
Category Storage
SubCategory TMP = Temperature
Severity Severity 2 (Warning)
Trap/EventID 4210
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
TMP1002
Message
arg1
has exceeded the maximum failure threshold.
Arguments
arg1 =
tempsensor name
Detailed
Description
The enclosure is too hot. A variety of factors can cause the excessive temperature. For
example, a fan may have failed, the thermostat may be set too high, or the room temperature
may be too hot.