Przeglądanie stron 707
Detailed
Description
None
Recommended
Response Action
No response action is required.
Category System Health
SubCategory SEL = Sys Event Log
Severity Severity 3 (Informational)
Trap/EventID 2379
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
SEL1501
Message Chassis management controller (CMC) redundancy is lost.
Detailed
Description
An action or failure has taken place that breaks CMC redundancy. This includes loss of
network connection, hardware failures, firmware update, firmware mismatch between CMCs,
CMC reset, and unplugging a CMC.
Recommended
Response Action
Check CMC network cables and network connections. Check that CMC firmware versions
match.
Category System Health
SubCategory SEL = Sys Event Log
Severity Severity 1 (Critical)
Trap/EventID 2377
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
SEL1502
Message Chassis management controller (CMC) redundancy is degraded.
Detailed
Description
An action or failure has taken place that degrades CMC redundancy. This includes firmware
mismatch between CMCs and a CMC missing SD card.
708