Dell Chassis Management Controller Version 4.50 Podręcznik Użytkownika Strona 424

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 428
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 423
Disabled
Default value
Write Privilege Server Control
License
Required
iDRAC7 Express or iDRAC7 Enterprise
Dependency None
Storage.Controller.RebuildRate (Read or Write)
Description The Rebuild Rate is the percentage of the system's resources dedicated to rebuilding a failed disk
when a rebuild is necessary.
Legal Values Values: 0–100
Default value
Write Privilege Server Control
License
Required
iDRAC7 Express or iDRAC7 Enterprise
Dependency None
Storage.Controller.ReconstructRate (Read or Write)
Description
The Reconstruct Rate is the percentage of the system's resources dedicated to reconstructing a
disk group after adding a physical disk drive or changing the RAID level of a virtual disk residing on
the disk group.
Legal Values Values: 0–100
Default value
Write Privilege Server Control
License
Required
iDRAC7 Express or iDRAC7 Enterprise
Dependency None
Storage.Controller.SupportControllerBootMode (Read Only)
Description
This is readonly attribute. This property indicates if this controller supports setting of controller boot
mode.
Legal Values
Supported
Not Supported
Default value
Write Privilege Configure iDRAC
License
Required
iDRAC7 Express or iDRAC7 Enterprise
424
Przeglądanie stron 423
1 2 ... 419 420 421 422 423 424 425 426 427 428

Komentarze do niniejszej Instrukcji

Brak uwag