
• Disabled
Default value
Write Privilege Server Control
License
Required
iDRAC7 Express or iDRAC7 Enterprise
Dependency None
Storage.Controller.RebuildRate (Read or Write)
Description The Rebuild Rate is the percentage of the system's resources dedicated to rebuilding a failed disk
when a rebuild is necessary.
Legal Values Values: 0–100
Default value
Write Privilege Server Control
License
Required
iDRAC7 Express or iDRAC7 Enterprise
Dependency None
Storage.Controller.ReconstructRate (Read or Write)
Description
The Reconstruct Rate is the percentage of the system's resources dedicated to reconstructing a
disk group after adding a physical disk drive or changing the RAID level of a virtual disk residing on
the disk group.
Legal Values Values: 0–100
Default value
Write Privilege Server Control
License
Required
iDRAC7 Express or iDRAC7 Enterprise
Dependency None
Storage.Controller.SupportControllerBootMode (Read Only)
Description
This is readonly attribute. This property indicates if this controller supports setting of controller boot
mode.
Legal Values
• Supported
• Not Supported
Default value
Write Privilege Configure iDRAC
License
Required
iDRAC7 Express or iDRAC7 Enterprise
424
Komentarze do niniejszej Instrukcji