BIOS.MemSettings.MemOpMode (Read Only)
Description
Current memory operating mode.
Legal Values
OptimizerMode
SpareMode
MirrorMode
AdvEccMode
SpareWithAdvEccMode
Write Privilege
Server Control
License
Required
iDRAC7 Express or iDRAC7 Enterprise
Dependency
None
BIOS.MemSettings.MemOptimizer (Read or Write)
Description
Configure the memory optimizer setting.
Legal Values
Enabled
Disabled
Write Privilege
Server Control
License
Required
iDRAC7 Express or iDRAC7 Enterprise
Dependency
None
BIOS.MemSettings.MemOpVoltage (Read Only)
Description
Operating voltage of memory.
Legal Values
AutoVolt
Volt15V
Write Privilege
Server Control
License
Required
iDRAC7 Express or iDRAC7 Enterprise
Dependency
None
BIOS.MemSettings.MemTest (Read or Write)
Description
Specifies whether BIOS software-based system memory tests are conducted during POST.
Legal Values
Enabled
Disabled
Write Privilege
Server Control