Dell Chassis Management Controller Version 4.50 Podręcznik Użytkownika Strona 260

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 428
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 259
1 — Enabled
Default Value
0 — For platforms that do not support PCIe cards.
500 W — For platforms that support PCIe cards.
Write Privilege
Configure iDRAC
License
Required
iDRAC7 Express or iDRAC7 Enterprise
Dependency
None
System.Power.PFCEnable (Read or Write)
Description
Enables the power factor correction enable.
NOTE:
This object is supported only for iDRAC on Rack and Tower servers.
This object is applicable only if System.Power.Cap.Enable is set to 1.
Legal Values
0 — Disabled
1 — Enabled
Default Value
0 — Disabled
Write Privilege
Configure iDRAC
License
Required
iDRAC7 Express or iDRAC7 Enterprise
Dependency
None
System.Power.RedundancyCapabilities (Read Only)
Description
Returns the redundancy capabilities in the form of a bitmask. This bitmask indicates the values that
are set to cfgSensorRedundancyPolicy.
NOTE: This object is not applicable on iDRAC on Blade servers.
Legal Values
A Bit Mask.
More than 1 bit can be set at a time to indicate multiple redundancy support.
0 — not applicable
1 — Non-Redundant
2 — 1+1 Redundant
4 — 2+1 Redundant
8 — 2+2 Redundant
16 — 3+x Redundant
32 — 4+x Redundant
64 — 5+x Redundant
260
Przeglądanie stron 259
1 2 ... 255 256 257 258 259 260 261 262 263 264 265 ... 427 428

Komentarze do niniejszej Instrukcji

Brak uwag