Dell Chassis Management Controller Version 4.50 Podręcznik Użytkownika Strona 422

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 428
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 421
Dependency None
Storage.Controller.CheckConsistencyRate (Read or Write)
Description The Check Consistency rate is the percentage of the system's resources dedicated to performing a
check consistency on a redundant virtual disk.
Legal Values Values: 0–100
Default value
Write Privilege Server Control
License
Required
iDRAC7 Express or iDRAC7 Enterprise
Dependency None
Storage.Controller.ControllerBootMode (Read or Write)
Description
This property indicates the Controller Boot Mode setting on the controller.
Legal Values
User Mode
Continue Boot On Error
Headless Mode Continue On Error
Headless Safe Mode
Default value
Write Privilege Server Control
License
Required
iDRAC7 Express or iDRAC7 Enterprise
Dependency None
Storage.Controller.CopybackMode (Read or Write)
Description
This attribute represents the mode of restoring the configuration of a virtual disk when a failed
physical disk drive is replaced in an array.
Legal Values
On
ON with SMART
Off
Default value
Write Privilege Server Control
License
Required
iDRAC7 Express or iDRAC7 Enterprise
Dependency None
422
Przeglądanie stron 421

Komentarze do niniejszej Instrukcji

Brak uwag