Host Name =
OS Name =
OS Version =
Power Status = ON
Fresh Air Capable = Yes
Watchdog Information:
Recovery Action = None
Present countdown value = 15 seconds
Initial countdown value = 15 seconds
Embedded NIC MAC Addresses:
NIC.Embedded.1-1-1 Ethernet = 90:B1:1C:11:3C:B5
WWN = 90:B1:1C:11:3C:B5
NIC.Embedded.2-1-1 Ethernet = 90:B1:1C:11:3C:B6
WWN = 90:B1:1C:11:3C:B6
gettracelog
Description
Lists all the trace login entries iDRAC and CMC.
Synopsis
• racadm gettracelog -i [-A]
• racadm gettracelog [-s <start>] [-c <count>] [--more] [-A] [-o]
Input
• —i — Displays the number of entries in iDRAC trace log.
• --more — Displays one screen at a time and prompts the user to continue (similar to the UNIX
more command).
• -o — Displays each entry in a single line.
• -c — Specifies the number of records to display.
• -s — Specifies the starting record to display.
• -A — Does not display headers or labels.
NOTE: For CMC: the -A and -o options are deprecated.
Output
The default output display shows the record number, timestamp, source and description. The
timestamp begins at midnight, January 1 and increases until the system startx. After the system
starts, the system’s timestamp is used.
Example
Record: 1
Date/Time: Dec 8 08:21:30
Source: ssnmgrd[175]
Description: root from 143.166.157.103: session timeout
sid 0be0aef4
getversion
Description
Displays the current software version, model and generation information, and whether the target
device can be updated.
To use this subcommand, you must have a login user privilege.
Synopsis
• racadm getversion [-b | -c] [-m <module>]
84