– disabled — Does not allow the virtual disk to use the cache.
– default — Uses the default cache policy. For SAS drives, use the disabled option and
for SATA drives, use the
enabled option by default.
• -name <VD name> — Specifies the name of the virtual disk.
• -size <VD size> — Specifies the size of each virtual disk.
– b — Specifies the size in bytes
– k — Specifies the size in kilobytes
– m — Specifies the size in megabytes
– g — Specifies the size in gigabytes
– t — Specifies the size in terabytes
• -sc — Number of spans in a virtual disk (required for multi-span RAID level).
NOTE:
– The default value for multi-span RAID levels is 2 and for basic RAID levels is 1.
– For hybrid RAID levels such as RAID10 and RAID50, -sc option is mandatory.
– The value for-sc option can be 0 only for RAID10.
– After creating the virtual disk, create a job and to apply the virtual disk configuration,
restart the server operating system.
• -T10PIEnable — Creates a virtual disk with protection information.
• -key <Key id> — Specifies the key id.
• -passwd <passphrase> — Specifies the passphrase.
• -newpasswd <passphrase> — Specifies the new passphrase.
• -assign {yes | no} — Assigns or unassigns the disk as a hot-spare.
• -type { ghs | dhs} — Assigns a global or dedicated hot-spare.
• -vdkey:<VD FQDD> — Assigns the dedicated hot-spare to the specified virtual disk. This
option is required for dedicated hot-spare.
Example
• To generate and view information about the inventory of controllers, virtual disks, storage enclosures, and physical
disk drives.
– To generate and view information about the inventory of storage root node.
This command retrieves the status.
racadm raid get status
Storage Root Node Status : Ok
– To generate and view information about the inventory of controllers connected to the server.
racadm raid get controllers
RAID.Integrated.1-1
This command is an optimized version and displays the full controller objects along with their keys.
racadm raid get controllers -o
RAID.Integrated.1-1Status = Ok
DeviceDescription = Integrated RAID Controller 1
RollupStatus = Ok
Name = PERC H710P Adapter (Embedded)
FirmwareVersion = 21.2.0-0007
DriverVersion = 6.600.18.00
RebuildRate = 30 %
BgiRate = 30 %
CheckConsistencyRate = 30 %