disabled — Does not allow the virtual disk to use the cache.
default — Uses the default cache policy. For SAS drives, use the disabled option and
for SATA drives, use the
enabled option by default.
-name <VD name> — Specifies the name of the virtual disk.
-size <VD size> — Specifies the size of each virtual disk.
b — Specifies the size in bytes
k — Specifies the size in kilobytes
m — Specifies the size in megabytes
g — Specifies the size in gigabytes
t — Specifies the size in terabytes
-sc — Number of spans in a virtual disk (required for multi-span RAID level).
NOTE:
The default value for multi-span RAID levels is 2 and for basic RAID levels is 1.
For hybrid RAID levels such as RAID10 and RAID50, -sc option is mandatory.
The value for-sc option can be 0 only for RAID10.
After creating the virtual disk, create a job and to apply the virtual disk configuration,
restart the server operating system.
-T10PIEnable — Creates a virtual disk with protection information.
-key <Key id> — Specifies the key id.
-passwd <passphrase> — Specifies the passphrase.
-newpasswd <passphrase> — Specifies the new passphrase.
-assign {yes | no} — Assigns or unassigns the disk as a hot-spare.
-type { ghs | dhs} — Assigns a global or dedicated hot-spare.
-vdkey:<VD FQDD> — Assigns the dedicated hot-spare to the specified virtual disk. This
option is required for dedicated hot-spare.
Example
To generate and view information about the inventory of controllers, virtual disks, storage enclosures, and physical
disk drives.
To generate and view information about the inventory of storage root node.
This command retrieves the status.
racadm raid get status
Storage Root Node Status : Ok
To generate and view information about the inventory of controllers connected to the server.
racadm raid get controllers
RAID.Integrated.1-1
This command is an optimized version and displays the full controller objects along with their keys.
racadm raid get controllers -o
RAID.Integrated.1-1Status = Ok
DeviceDescription = Integrated RAID Controller 1
RollupStatus = Ok
Name = PERC H710P Adapter (Embedded)
FirmwareVersion = 21.2.0-0007
DriverVersion = 6.600.18.00
RebuildRate = 30 %
BgiRate = 30 %
CheckConsistencyRate = 30 %