Input
• —u — For iDRAC: The update option performs a checksum of the firmware update file and starts
the actual update process. This option may be used along with the —g or —p options. At the end
of the update, iDRAC performs a soft reset.
For CMC: Performs the firmware update operation.
• —s — For iDRAC: This option returns the status of the update process. Use this option by itself.
Lists active SD card features and SD card status.
For CMC: Displays the status of the firmware update.
NOTE: Use —m to display the status of the module update. Omit -m to display the status of the
active CMC update.
NOTE: The value all is used only to obtain the status of all targets to update.
• -g — For iDRAC: The get option instructs the firmware to get the firmware update file from the
TFTP server. Specify the -a-u, and —d options. In the absence of the —a option, the defaults are
read from properties contained in the group cfgRemoteHosts , using
properties
cfgRhostsFwUpdateIpAddr and cfgRhostsFwUpdatePath.
For CMC: Downloads the firmware update using the TFTP server.
• -a — The IP Address option specifies the TFTP server IP address, used with -g option.
For CMC: Specifies the TFTP server IP address or FQDN used for the firmware image (used with -
g).
• -d — For iDRAC: The -d, or directory option specifies the directory on the TFTP server or on
iDRAC’s host server, where the firmware update file resides.
For CMC: Specifies the source path where the firmware image resides.
Default: Designated TFTP default directory on that host for the file if -g option is absent. If -g
is used, it defaults to a directory configured on the TFTP server.
• -p — For iDRAC: The -p, or put, option is used to update the firmware file from the managed
system to iDRAC. The
-u option must be used with the -p option.
NOTE: This option is not applicable for CMC. The-p option is supported on local and remote
RACADM and is not supported with the
serial/Telnet/ssh console and on the Linux
operating systems.
• -r — The rollback option is used to roll back to the standby firmware.
This option is not applicable for CMC.
• -p — Stops the current firmware update of a module.
This option is applicable only for CMC.
• -m <module> — Specifies the module or device to be updated. <module> is one of the
following values:
– —cmc-active(default)
– —cmc-standby
– —kvm
– server-<n> where n=1–16
– —server-nx where n=1–8; x = a,b,c,d
– —server-g <generation>, where generation = iDRAC or iDRAC6 only.
– —iominf-n where n = 1–6
• -f— Specifies the FTP server IP address or FQDN, username, and password used for firmware
image. Applies FTP download process for firmware update.
• --clearcfg (Optional) — After the firmware update, this option removes the previous iDRAC
configuration.