Dell Chassis Management Controller Version 4.50 Podręcznik Użytkownika Strona 113

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 428
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 112
ManufacturedYear = 2012
SasAddress = 0x5000C5005952386D
FormFactor = 2.5 Inch
RaidNominalMediumRotationRate = 10000
T10PICapability = Not Capable
BlockSizeInBytes = 512
MaxCapableSpeed = 6 Gb/s
This command is an optimized and filtered version.
racadm raid get pdisks --refkey Enclosure.Internal.0-1:RAID.Integrated.
1-1 -o -p State
Disk.Bay.0:Enclosure.Internal.0-1:RAID.Integrated.1-1
State = Online
To generate and view information about the inventory of fans connected to the enclosure.
This command displays all the fan keys connected to the enclosures.
racadm raid get fans --refkey <enclosure FQDDs separated
by comma>
This command displays all the fan objects for the enclosure FQDD.
racadm raid get fans --refkey <enclosure FQDDs separated
by comma > -o
racadm raid get fans --refkey <enclosure FQDDs separated
by comma> -o -p <property names separated by comma>
To generate and view information about the inventory of EMMs connected to the enclosure.
This command returns all the EMM keys connected to the enclosures.
racadm raid get emms -refkey <enclosure FQDDs separated
by commaenclosure FQDDs separated
by comma>
This command is an optimized version and displays all the EMM objects for the enclosure FQDD.
racadm raid get emms --refkey <enclosure FQDDs separated
by comma> -o
This command is an optimized and filtered version.
racadm raid get emms --refkey <enclosure FQDDs separated
by comma > -o -p <property names separated by comma>
To generate and view information about the inventory of PSU connected to the enclosure.
This command displays all the PSUs connected to the enclosures.
racadm raid get psus --refkey <enclosure FQDD's separated
by comma>
This command is an optimized version and displays all the PSUs objects for the enclosure FQDD.
racadm raid get psus --refkey <enclosure FQDD's separated
by comma > -o
This command is an optimized and filtered version.
racadm raid get psus --refkey <enclosure FQDD's separated
by comma> -o -p <property names separated by comma>
To create, delete, and secure the virtual disks.
This command creates a virtual disk.
racadm raid createvd:RAID.Integrated.1-1 -rl r0 -pdkey:Disk.Bay.
0:Enclosure.Internal.0-0:RAID.Integrated.1-1
This command starts an initialization operation on a specified virtual disk.
racadm raid init:Disk.Virtual.0:RAID.Integrated.1-1 -speed fast
113
Przeglądanie stron 112
1 2 ... 108 109 110 111 112 113 114 115 116 117 118 ... 427 428

Komentarze do niniejszej Instrukcji

Brak uwag