Dell Chassis Management Controller Version 4.50 Podręcznik Użytkownika Strona 234

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 428
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 233
cfgIpmiSerialChanPrivLimit (Read or Write)
Description
Specifies the maximum privilege level allowed on the IPMI serial channel.
Legal Values
2 (User)
3 (Operator)
4 (Administrator)
Default
4
cfgIpmiSerialConnectionMode (Read or Write)
Description
When the iDRAC cfgSerialConsoleEnable property is set to 0(disabled), the iDRAC serial
port becomes the IPMI serial port. This property determines the IPMI defined mode of the serial port.
In Basic mode, the port uses binary data with the intent of communicating with an application
program on the serial client. In Terminal mode, the port assumes that a dumb ASCII terminal is
connected and allows simple commands to be entered.
Legal Values
0(Terminal)
1(Basic)
Default
1
cfgIpmiSerialDeleteControl (Read or Write)
Description
Enables or disables delete control on the IPMI serial interface.
Legal Values
0 (FALSE)
1 (TRUE)
Default
0
cfgIpmiSerialEchoControl (Read or Write)
Description
Enables or disables echo control on the IPMI serial interface.
Legal Values
0(FALSE)
1 (TRUE)
Default
1
cfgIpmiSerialFlowControl (Read or Write)
Description
Specifies the flow control setting for the IPMI serial port.
Legal Values
0 (None)
1 (CTS or RTS)
234
Przeglądanie stron 233
1 2 ... 229 230 231 232 233 234 235 236 237 238 239 ... 427 428

Komentarze do niniejszej Instrukcji

Brak uwag