
– This command deletes the specified virtual disk.
racadm raid deletevd:Disk.Virtual.0:RAID.Integrated.1-1
– This command encrypts the specified virtual disk.
racadm raid encryptvd:Disk.Virtual.0:RAID.Integrated.1-1
NOTE: Virtual disk must be created with SED.
– This command assigns security key for controller.
racadm raid createsecuritykey:RAID.Integrated.1-1 -key <Key id> -passwd
<passphrase>
– This command modifies security key for controller.
racadm raid modifysecuritykey:RAID.Integrated.1-1 -key <Key id> -
oldpasswd <oldpassphrase> -newpasswd <newpassphrase>
– This command deletes security key for controller.
racadm raid deletesecuritykey:RAID.Integrated.1-1
• To convert the physical disk drive and assign hot-spare.
– This command converts the specified non-RAID physical disk drive to a RAID capable physical disk drive.
racadm raid converttoraid:Disk.Bay.0:Enclosure.Internal.
0-0:RAID.Integrated.1-1
– This command converts the specified physical disk drive to a non-RAID physical disk drive.
racadm raid converttononraid:Disk.Bay.0:Enclosure.Internal.
0-0:RAID.Integrated.1-1
– This command assigns or unassign a global or dedicated hot-spare.
racadm raid hotspare:Disk.Bay.0:Enclosure.Internal.0-0:RAID.Integrated.
1-1 -assign no
racadm raid hotspare:Disk.Bay.0:Enclosure.Internal.0-0:RAID.Integrated.
1-1 -assign yes -type ghs
racadm raid hotspare:Disk.Bay.0:Enclosure.Internal.0-0:RAID.Integrated.
1-1 -assign yes -type dhs -vdkey:Disk.Virtual.0:RAID.Integrated.1-1
• To reset, clear, and import the RAID configuration to the controller.
– This command imports the current foreign configuration from the controller.
racadm raid importconfig:RAID.Integrated.1-1
– This command clears the current foreign configuration from the controller.
racadm raid resetconfig:RAID.Integrated.1-1
– This command deletes the virtual disk from the controller.
racadm raid clearconfig:RAID.Integrated.1-1
NOTE: After a resetconfig or clearconfig operation, the data cannot be reversed.
remoteimage
Description Connects, disconnects, or deploys a media file on a remote server.
To run this subcommand, you must have the Administrator privilege.
Synopsis
racadm remoteimage <options>
Input
• -c — Connect the image.
• -d — Disconnect image.
114
Komentarze do niniejszej Instrukcji