Dell Chassis Management Controller Version 4.50 Podręcznik Użytkownika Strona 49

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 428
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 48
cmc-n — where n=1, 2
fan-n — where n=1–9
ps-n — where n=1–6
chassis
kvm
lcd
NOTE: A few of the informational messages are applicable for more than one module. To avoid
repetition of the same message for different modules, only one such informational message is
displayed for the default command racadm getactiveerrors. When an -m option is
used on another server or switch, the informational message is displayed, if applicable.
After you run this command, the full-height, half-height, and the quarter-height servers and
switches are automatically checked for informational messages (in the same order as
mentioned here).
Examples
To display the entire log (Critical, Warning and Informational messages) for all modules.
racadm getactiveerrors
Module ID = server-1
Severity = Critical
Message = The storage battery has failed.
Module ID = server-10
Severity = Critical
Message = General failure after video.
Module ID = ps-6
Severity = Critical
Message = The power input for power supply 6 is lost.
To display Critical error messages for all the components.
racadm getactiveerrors –s critical
Module ID = server-1
Severity = Critical
Message = The storage battery has failed.
Module ID = server-10
Severity = Critical
Message = General failure after video.
Module ID = ps-6
Severity = Critical
Message = The power input for power supply 6 is lost.
To display critical error messages for server–1.
racadm getactiveerrors –s critical –m server-1
There are no critical alerts
Module ID = server-1
Severity = Critical
Message = The storage battery has failed.
The error message displayed for invalid syntax.
racadm getactiveerrors –z cmc-1
ERROR: The syntax of the command specified is not correct.
The error message displayed for invalid parameter.
racadm getactiveerrors –m server-80
ERROR: The syntax of the command specified is not correct.
49
Przeglądanie stron 48
1 2 ... 44 45 46 47 48 49 50 51 52 53 54 ... 427 428

Komentarze do niniejszej Instrukcji

Brak uwag