only be a single update operation in progress at any time. In addition, the fwupdate subcommand
may only update one or more devices of a single kind at a time.
To use this subcommand for CMC, you must have the Chassis Configuration Administrator privilege
and for iDRAC you must have Configure iDRAC permission.
NOTE:
Running the fwupdate subcommand to update the firmware on the active CMC resets itself
and all the network connections are dropped. During update of all other modules, including
the standby CMC, the active CMC continues to run normally without resetting.
In a chassis supported by DC PSUs, an error message is displayed if you attempt to update
the firmware with a version without DC PSU support.
NOTE: The fwupdate subcommand generates an error when used on the extension slot of a
multi-slot server.
Synopsis
For iDRAC:
racadm fwupdate -s
racadm fwupdate -g -u -a <TFTP_Server_IP_Address>
[-d <path> [--clearcfg]
racadm -r <iDRAC7 IP_Address> -u <username> -p <password> fwupdate
-f <ftpserver ip> <ftpserver username> <ftpserver password> -d
<path> where path is the location on the ftp server where
firming.d7 is stored.
racadm fwupdate -r
racadm fwupdate -p -u [-d <path>]
For CMC:
For local RACADM:
racadm fwupdate -g -u -a <tftp server ip address or
FQDN> -d <path> [-m <module>]
racadm fwupdate -f <ftp server ip address or FQDN>
<username> <password> -d <path> [-m
<module>]
racadm fwupdate -u -m iominf-<n>
racadm fwupdate -s [-m <module>]
racadm fwupdate -c [-m <module>]
For Remote RACADM:
racadm fwupdate -p -u -d <firmware image>
NOTE: iDRAC7 targets are not supported from CMC. To update iDRAC7 targets, use the CMC
GUI.
When using FTP, if you provide the full path to the image file on theCLI, then the CMC uses that
path to locate that file on the host. If full path is not provided and the host system is running Linux or
another variant of UNIX , then CMC searches the home directory of the specified user for the file. If
the host system is running Windows, then a default folder, such as C:\ftproot is searched.
NOTE: When attempting to run firmware update task using racadm fwupdate command, if the
firmware image path length is greater than 256 characters. Remote RACADM client exits with
the error message "ERROR: Specified path is too long".